Shop

Hot Sale spectrum Spa Dome / Far Infrared Sauna Dome
April 3, 2019
Massage Pillow
April 4, 2019
Show all

Microcirculation Nailfold Cappillaroscopy

Product Enquiry
Category:
Description

Non-intrusive video clinic capillaroscope blood analysis machine

Microcirculation Detector Parameter
Packing Dimfnsing
37.5*26.5*34cm
Amplification
380X or 240X
Input
AC input 100-240V50/60Hz DC
Output
DC12V,2A
Objective
5X,effective range 25mm
Objective type
Achromatization
Mechanical stage
X-Y double layer compound mechanical stage
Focusing mechanism
Coaxial coarse and fine adjustment
Inner dimming
LED cold light
Type
I or B
Power
12V,1A, DC power source
Built-in camera
80 000 pixels
LCD monitor
8inch,9inch Color LCD monitor
Certificate
CE approved
Net weight
6KG
Gross weight
7KG
Inner package
Aluminum password box, memory foam
Out package
Corrugated box

About Nailfold Capillaroscopy Microcirculation Detector

Microcirculation is the circulation of the blood in the smallest blood vessels,present in the vasculature embedded within organ tissues. This contrasts with macrocirculation, which is the circulation of blood to and from the organs. Microcirculation is composed of terminalarterioles, capillaries capillaries and venules which drain capillary blood. The vessels on the arterial side of the microcirculation are called the arterioles, which are well innervated, are surrounded by smooth musclecells, and are 10-100 µm in diameter.

Microcirculation is usually very smooth, but by high blood lipids, blood viscosity, erythrocyte aggregation, affect cardiovascular disease and other factors, microcirculation appears white tiny blood clots, which with the blood flow in the body.

Once the blood vessels become thin, distorted and clog the blood vessels (especially the elderly), there will be a corresponding disease, ranging from dizziness, insomnia, dizziness, numb lips, palpitation, chest tightness. If there is a large area of the brain or heart blockage will cause hemiplegia, language barriers, myocardial infarction. Therefore, early detection of thrombosis should check the microcirculation by actively antithrombotic thrombolysis, and clear the microcirculation, preventive measures.


Currently, the primary means of discovery is microcirculation microcirculation microscopic examination instrument, and general such as CT, MRI, X-ray, B-and so can not be found, so the clinical microcirculation earlier than macroscopic examination has found early diagnosis role.
Meanwhile, health groups and immunocompromised people are mainly in the microcirculation, lack of microvascular perfusion, vascular blurred, slow blood flow. By detecting the microcirculation can also quickly find the body in which the current situation in a timely manner as soon as possible be microcirculation, increase resistance and immunity, improve the sub-health conditions.

The Nailfold Capillaroscopy Microcirculation Microscope is an advance medical photoelectric apparatus,equipped with built in special LED light source,used mainly in observation on human nail fold capillary microcirculation or term as video Nailfold capillaroscopy,Such as capillary blood flow, abnormal microcirculation of the vascular structure, cell adhesion, through its powerful 380X(or 240X)optical magnification. Undistorted, real time dynamic video streaming via Sony CCD imaging device onto the LCD monitor screen.

Simply insert the finger to the holder below the optical lens apparatus, fine-tune to fix the focal length and uncover the desired images within seconds.Blood capilliary microcirculation microscope is a non-invasive diagnostic tools, which is gaining large credit among physicians of different specialities in for study of skin blood capilliary network.

 Product Features

 It is not a invaded method to inspect the blood micro-circulate situation for the body.

 The blood micro-circulate inspect the health situation by view perspective.
It is a contact process. It can search the tip blood capillary position in 5 second. Easy operation (not traditional XY goods)
The micro-image is stable, clear and not move for contact process.

360 times, high definition lens for micro-circulate machine
Light frame and easy to carry
Portable light design(250g)
The lens can be exactly adjusted a focal distance to make the image clear
Lens with LED light, the light can throw straight on a target.
(1)Can be observed in 5 seconds microvascular circulation, simple operation, fast. 

(2)Microscopic displays image stability, clear and not shake.
(3)3400 times of microcirculation for high resolution microscopy.
(4)Handheld ultra lightweight design, make observation more action.
(5)With micro focus wheel, can adjust the focal length, more convenience.
(6)Inner objective with LED cold light,can provide accurate projection illumination on the target.
(7)Using non-intrusive way, observing blood microcirculation status in a timely manner. 

(8)Can observation microcirculation For any parts of body.

Application

(1)A wall of peripheral microcirculation observation

(2)Skin peripheral microcirculation observation 

(3)Sweat glands observation
(4)Follicle observation

Usage of  microcirculation nailfold capillaroscopy machine

1.Fix the screen on the top of the mechanical machines.

2.Plug in the power line and vidao line to the interface of the base.

3. Connect the plug, the plug shows green lights. Press the “Power” button of the screen, wait 3 seconds, the screnn will light.

4.Paint three drops of oil at the position of the intersection of the ring finger nails and skin. Put the oil coated finger in finger hold.

5. Adjust the coarse hand wheel, when the screen displays images, then adjust fine handwheel. Picture becomes clearer. The bigger one is the coarse adjustable wheel and the small wheel is the fine handwheel. When the machine is about 2-3cm away from the finger, there will be a transparent image on screen.

6.Then, adjust platform lateral movement hand wheel to et a correct position of the first line of the vessel( capillary tube ) and adjust the fine coarse hand wheel to get a clear picture of the vessel. Your fingers will move from left to right on the double loading platform. So try to find the first line of vessels by rotating the platform lateral movement handwheel to change the position of the finger. And finally rotate the fine hand wheel ( the position is showed in the structure ) to get a clear picture of the vessels.

7.If there is spot on the screen, rotate the camera right and left to eliminate it.

Packaging Details:

Aluminum password box, memory foam, then out carton.

Accessories:
*Host X1pc,                       *Liquid crystal display X1pc,
*DC one second line X1pc,  *DC extended line X1pc ,

 *AV video line X1pc,           *Power adapter X1pc ,

 *Cedar oil X1pc,                 *Cotton swab* 1pc,        

 *Chart X1pc